Top 10 Best Backflow Prevention Valve

of November 2024
1
Best ChoiceBest Choice
Watts 3/4" 009M3 Backflow Preventer Reduced Pressure Zone Assembly RPZ 3/4
Watts Premier
Watts Premier
10
Exceptional
View on Amazon
2
Best ValueBest Value
Midline Valve 372U422-5 Inline Spring Loaded Check Valve, Backflow Prevention,
Midline Valve
Midline Valve
9.9
Exceptional
View on Amazon
3
Watts 9D-M2 Backflow Preventer Dual Check Valve with Intermediate Atmospheric
Watts
Watts
9.8
Exceptional
View on Amazon
4
Midline Valve 372D256 Inline Spring Loaded Check Valve, Backflow Prevention
Midline Valve
Midline Valve
9.7
Exceptional
View on Amazon
5
Rectorseal 97034 Extendable Backwater Valve, White
Rectorseal
Rectorseal
9.6
Exceptional
View on Amazon
6
Midline Valve 432U225 Swing Check Valve, Backflow Prevention, Lead-Free 3 in.
Midline Valve
Midline Valve
9.5
Excellent
View on Amazon
7
WHK Hose Bib Backflow Preventer Vacuum Breaker,Garden Hose Check Valve to
WHK
WHK
9.4
Excellent
View on Amazon
8
Midline Valve PVC Inline Check Valve for Backflow Prevention 1-1/2'' Solvent
Midline Valve
Midline Valve
9.3
Excellent
View on Amazon
9
Rectorseal 97026 Clean Check Backwater Valve, White
Rectorseal
Rectorseal
9.2
Excellent
View on Amazon
10
Watts Backflow Preventer 3/4 In Water Pressure Reducing Valve, Npt Thread Union
Watts
Watts
9.1
Excellent
View on Amazon

About Backflow Prevention Valve

Click here to learn more about these products.

Watts 3/4" 009M3 Backflow Preventer Reduced Pressure Zone Assembly RPZ 3/4 009-QT 0063030 63030

Midline Valve 372U422-5 Inline Spring Loaded Check Valve, Backflow Prevention, Lead-Free 2 in. FIP Connections, Cast Brass (5 Pack), 2

Inner Spring Blocks Reverse Flow In Piping Systems. Heavy Duty Cast Brass Body And Disc Dezincification Resistant Corrosion Resistant Lead Free. Threaded Ends Comply With ANSI.B2.1. CSA Approved Conforms To NSFANSI-61372. 200 PSI CWP Non-Shock.

Watts 9D-M2 Backflow Preventer Dual Check Valve with Intermediate Atmospheric Vent, 3/4 Inch, Bronze

Made for smaller supply lines and ideally suited for laboratory equipment, processing tanks, sterilizers, dairy equipment and similar applications to prevent backflow. Suitable for use on hot or cold water and can be used under continuous pressure temperature range 33F 250F 0.5C 121C, maximum working pressure 175psi 12.1 bar, minimum required pressure 25psi 1.7 bar. Features a primary check valve utilizing a rubber disc seating against a mating rubber part to ensure tight closing and a secondary check valve utilizes a rubber disc-to-metal seating. Construction is bronze body with stainless steel working parts, integral strainer and durable rubber discs. To be installed at referenced cross-connections vertically or horizontally.

Midline Valve 372D256 Inline Spring Loaded Check Valve, Backflow Prevention Lead-Free, 3/4 in. Sweat Connections, Cast Brass

Inner Spring Blocks Reverse Flow In Piping Systems. Heavy Duty Cast Brass Body And Disc Dezincification Resistant Corrosion Resistant Lead Free. Solder Ends Comply With ANSI.B16.18. CSA Approved Conforms To NSFANSI-61372. 200 PSI CWP Non-Shock.

Rectorseal 97034 Extendable Backwater Valve, White

Prevent sewage backup into a residence or building. Easy to perform maintenance and inspection from ground level. -InchHands-off-Inch cleaning. Meetts all model construction and pumbing codes. NO costly manholes- direct bury upto 12 ft.

Midline Valve 432U225 Swing Check Valve, Backflow Prevention, Lead-Free 3 in. FIP Connections, Cast Brass, 3

Tilting Disc Blocks Reverse Flow In Piping Systems. Heavy Duty Cast Brass Body And Disc Dezincification Resistant Corrosion Resistant Lead Free. Threaded Ends Comply With ANSI.B2.1. CSA Approved Conforms To NSFANSI-61372. 200 PSI WOG 125 PSI WSP.

WHK Hose Bib Backflow Preventer Vacuum Breaker,Garden Hose Check Valve to Connect 3/4 Inch Outdoor Faucet Spigot,Sprinkler,RV,Anti-Siphon,2 Packs

Garden Hose Backflow Preventer MaterialThe material of bib hose backflow preventer is use solid 100 heavy duty brass,safety and duable.The hose bib vacuum breaker is high temperature ductility and low magnetic permeability.Meets ASSE 1011CSA B64.2 and ANSINSF 61-9 Standard.. Garden Hose Vacuum Breaker FeatureWHK Vacuum Breaker will prevent unclean water into drinking Manually drain the faucet and block water from freezing and Anti-siphone. 34-Inch self draining vacuum, breaker, Male hose thread, Break-off screw for permanent attachment.. Vacuum breaker Valve Size34-inch female hose threaded inlet,34-inch male hose threaded outlet.The -Inch thread outlet is apply for most of standard hose and end valves including hose bib, sillcocks, wall faucets,RV water lines and garden hose.. Garden Hose Check Valve Application Condition Max operating pressure is 125 psi Max operating temperature is 180F82C.. 100 Satisfaction Service and Package includesYou will receive 2 PCS hose backflow preventer1 PC Tape2 additional washers.If you are not completely satisfied our products,we will give you a replacement or a refund..

Midline Valve PVC Inline Check Valve for Backflow Prevention 1-1/2'' Solvent Connections White Plastic (4I2T112)

LEAK-FREE Features Secure, Leak-Free Solvent Connections. STAINLESS STEEL SPRING LOADED CHECK Prevents Backflow in Your Cold Water Pipes Not Recommended for Potable Water. SPECIFICATIONS Cracking Pressure .5 PSI 150 PSI at 73 Temperature Range 41- 140 ISO 9002 Approved Manufacturer ANSI.B1.20.1 and ASTM F1970 Approved. IDEAL FOR FLOW CONTROL IN Landscaping Sprinklers, Pools, Water Park, Aquarium, ETC. Can Be Installed Vertically and Horizontally.. PVC PIPING PVC Piping Systems Feature Improved Performance, Increased Safety, and Better Rust and Corrosion Resistance when Compared with Steel Piping Systems.

Rectorseal 97026 Clean Check Backwater Valve, White

Prevent sewage backup into a residence or building. Easy to perform maintenance and inspection from ground level. Meets all model construction and plumbing codes. NO costly manholes- direct bury up to 12 ft..

Watts Backflow Preventer 3/4 In Water Pressure Reducing Valve, Npt Thread Union X Npt Female, Max Work 400 psi, Adjust 25-75 psi

Installed at or near meters to cost-effectively control water pressure flowing to appliances and outlets in residential, commercial and industrial settings. Features a lead-free brass body an NPT threaded union female inlet by NPT female outlet connection an integral stainless steel strainer removable for cleaning a thermoplastic seat a bronze-sealed spring cage for accessible outdoor waterworks or pit installations and a thermal expansion bypass. Easily serviced for long-lasting life. Size is 7.38 x 5.63 x 2.44 inches.
Disclaimer